[Refactor] (docs/ci, MG_Impl/Pipe, MG_Remote/Client, MG_Test/Wire, scripts/data): drop the E2 drop knobs

- MOBILEGL_IPC_E2_DROP_DRAW and MOBILEGL_IPC_E2_DROP_CLEAR leave the shipped emitter with their per-draw and per-clear branches, setters, counters and per-frame evidence line; nothing sets them since the dropped-draws control left CI
- the wire-volume assertion on the OpenRA split legs replaces the control (758 DrawVbo records and 758/788 server draws locally, both backends, inproc and spawn)
- retire the unit case RemoteEmitTable.TheE2DropSwitchStartsDisarmed, which only toggled the clear setter; skip census: removed from junit-integration-split-strict/unit-strict (test/unit and unit-split borrow that list)
This commit is contained in:
2026-10-17 15:59:52 -04:00
parent 75edebdab7
commit 1e9f8bb0ff
7 changed files with 7 additions and 148 deletions
@@ -898,10 +898,6 @@ TEST(CapsMirrorTest, TheConsumerBlockDoesNotCollideWithTheFeatureBits) {
EXPECT_FALSE(CapsMirrorInstance().ServerConsumes(kMGPipeSubsystemSamplers));
}
// =====================================================================================
// E2's emitter-drop control: the switch itself, driven through the real emitter's own counter
// =====================================================================================
// =====================================================================================
// P5b d1: the draw family's record plan (docs/archive/contracts/CONTRACT-P5B.md §2 d1). These drive the
// PRODUCTION derivation the nineteen emitters call - PlanDrawInfo / PlanDrawRange /
@@ -1073,17 +1069,6 @@ TEST(RemoteEmitTable, TheNineteenDrawSlotsAreEmittersDistinctFromEveryStub) {
}
}
TEST(RemoteEmitTable, TheE2DropSwitchStartsDisarmed) {
// The half a unit case can state. E2's statement - "drop one Clear emission and OpenRA's
// SSIM falls below 0.99" - is a TRACE LANE's, because the picture is the thing it is about;
// what belongs here is that the control is off unless someone armed it, so a lane that
// forgot to disarm cannot look like a lane that was never armed.
EXPECT_EQ(DroppedClearEmissions(), 0u);
SetDropClearEmissionForNegativeControl(true);
SetDropClearEmissionForNegativeControl(false);
EXPECT_EQ(DroppedClearEmissions(), 0u) << "arming and disarming the control must not, by itself, drop anything";
}
// =====================================================================================
// ID-47: a readback larger than a reply slot is refused at the CLIENT, by name
// =====================================================================================