mirror of
https://github.com/MobileGL-Dev/MobileGL
synced 2026-11-20 08:21:56 +09:00
[Test, CI] (scripts/ci, workflows): E2's draw-drop control requires the SSIM red AND the library's dropped-record count, E3(a) requires its private-log line as well as the pixels, and the smoke red-check finally perturbs the split control (ID-65)
This commit is contained in:
@@ -48,10 +48,21 @@ def main():
|
||||
for path in selected.values():
|
||||
Path(path).unlink(missing_ok=True)
|
||||
elif mode == "evidence":
|
||||
# argv[5], optional: the control's name, for the failure message. Without it the message
|
||||
# is E1's, word for word - scripts/ci/testdata/split_private_log_smoke.sh greps for that
|
||||
# sentence, and E1 was the only caller until E3(a) gained a library diagnostic of its own
|
||||
# (ID-65: "no library diagnostic exists for block size 0 - x2 adds one").
|
||||
label = sys.argv[5] if len(sys.argv) > 5 else ""
|
||||
for name, path in selected.items():
|
||||
if Path(path).is_file() and re.search(sys.argv[4], Path(path).read_text(errors="replace")):
|
||||
print(f"private-log evidence: {name}: {path}")
|
||||
return
|
||||
if label:
|
||||
raise ValueError(f"{label} FAILED: no selected private log carries /{sys.argv[4]}/. "
|
||||
"The library's own line is the only channel for this: ctest's "
|
||||
"transcript is a FALSE ZERO for library output, because the console "
|
||||
"sink is compiled out of the configurations these lanes run. "
|
||||
+ ", ".join(f"{n} ({p})" for n, p in selected.items()))
|
||||
raise ValueError("E1 FAILED: selected private logs lack expected Fatal{BarrierViolation, \"<slot>\"} line: "
|
||||
+ ", ".join(f"{n} ({p})" for n, p in selected.items()))
|
||||
else:
|
||||
|
||||
Reference in New Issue
Block a user