mirror of
https://github.com/MobileGL-Dev/MobileGL
synced 2026-11-07 18:13:23 +09:00
- docs/Disaggregated/notes/p7/x2-caps-flake.md: the failure text (Fatal{ProtocolCorruption,
"StreamLink"} invalid data frame header, SIGABRT), the mechanism (ConnectTo/AcceptPair pairs
two loopback TCP connections by accept order and the kernel reorders them under load: 5 of
3000 in a raw-socket probe), the TEST verdict against the product's DataBind rendezvous, the
before/after loop counts (2/500, 5/500, 3/500 -> 0/500 x3 under the same load) and the gate
numbers (unit 2435/2435, census 79, ratchet 173, G1 .text 0xa52203 and +0/-0 symbols)
- open: AcceptPair/ConnectTo over tcp:// are still callable and still pair by order; refusing
them by name is a product change with its own red-once